CJ20 220V coil 3 phase magnetic AC electrical contactor
1.Features of CJ20 220V coil 3 phase magnetic AC electrical contactor:
1.For long-distance making and breaking circuit and frequently start and control AC electric motors.
2.key feature is that the controlling circuit power is electrically isolated from the circuit(s) being switched.
3.Contacts can also be assembled into a modular auxiliary contact group, air delayer, mechanical interlocking institutions and other accessories.
4.Made of high quality materials, Durable and reliable with long service life.
5.Standard: GB14048.4 IEC 60947-4-1.
Type | Insulation Voltage (V) | Rated working voltage (V) | Appointed free air heating current (A) | Rated working current (AC-3)(A) | Rated power control (AC-3)(KW) | Rated operating frequency (AC-3)(time/hour) | Choose the fuse (SCPD) model | Action feature | Coil power control (VA/W) |
|
Start | Attract | |||||||||
CJ20-10 | 690 | 220 | 10 | 10 | 2.2 | 1200 | NT00-20/660 | The pull in voltage range 0.85-1.1Us Release voltage range 0.2-0.75Us | 65/47.6 | 8.3/2.5 |
380 | 10 | 4 | 1200 | |||||||
660 | 5.2 | 4 | 600 | |||||||
CJ20-16 | 220 | 16 | 16 | 4.5 | 1200 | NT00-32/660 | 65/47.8 | 8.5/2.6 | ||
380 | 16 | 7.5 | 1200 | |||||||
660 | 13 | 11 | 600 | |||||||
CJ20-25 | 220 | 32 | 25 | 55.5 | 1200 | NT00-50/660 | 93.1/60 | 13.9/41 | ||
380 | 25 | 11 | 1200 | |||||||
660 | 14.5 | 13 | 600 | |||||||
CJ20-40 | 220 | 55 | 40 | 11 | 1200 | NT00-80/660 | 175/82.3 | 19/5.7 | ||
380 | 40 | 22 | 1200 | |||||||
660 | 25 | 22 | 600 | |||||||
CJ20-63 | 220 | 80 | 63 | 18 | 1200 | NT1-160/660 | The pull in voltage range | 480/153 | 57/16.5 | |
380 | 63 | 30 | 1200 | |||||||
660 | 40 | 35 | 600 | |||||||
CJ20-100 | 220 | 125 | 100 | 28 | 1200 | NT1-250/660 | 570/178 | 61/21.5 | ||
380 | 100 | 50 | 1200 | |||||||
660 | 63 | 50 | 600 | |||||||
CJ20-160 | 220 | 200 | 160 | 48 | 1200 | NT2-315/660 | Release voltage range | 855/32 | 85.6/34 | |
380 | 160 | 85 | 1200 | |||||||
660 | 100 | 85 | 600 | |||||||
CJ20-160/11 | 1140 | 1140 | 200 | 80 | 85 | 300 | ||||
CJ20-250 | 690 | 220 | 315 | 250 | 80 | 600 | NT2-400/660 | The pull in voltage range 0.85-1.1Us Release voltage range 0.2-0.75Us | 570/175 | 152/65 |
380 | 250 | 132 | 600 | |||||||
CJ20-250/06 | 660 | 200 | 190 | 300 | ||||||
CJ20-400 | 220 | 400 | 400 | 115 | 600 | NT2-500/660 | 3578/790 | 250/118 | ||
380 | 400 | 200 | 600 | |||||||
CJ20-400/06 | 660 | 250 | 220 | 300 | ||||||
CJ20-630 | 220 | 630 | 630 | 175 | 600 | NT3-630/660 | 3578/790 | 250/118 | ||
380 | 630 | 300 | 600 | |||||||
CJ20-630/06 | 660 | 400 | 400 | 350 | 300 | |||||
CJ20-630/11 | 1140 | 1140 | 400 | 400 | 120 |
- The external fixing dimension
Type | A max | B max | C max | a | b | Φ | F min | L |
CJ20-10 | 44.5 | 67.5 | 107 | 35 | 55 | 5 | 10 | 8 |
CJ20-16 | 44.5 | 73 | 116.5 | 35 | 60 | 5 | 10 | 8 |
CJ20-25 | 52.5 | 90.5 | 122 | 40 | 80 | 5 | 10 | 7.5 |
CJ20-40 | 87 | 112.5 | 125 | 70 | 80 | 5 | 30 | 15.5 |
CJ20-63 | 116 | 142 | 146 | 100 | 90 | 5.8 | 60 | 10 |
CJ20-100 | 122 | 147 | 154 | 108 | 92 | 7 | 70 | 15 |
CJ20-160 | 146 | 187 | 178 | 130 | 130 | 9 | 80 | 15 |
CJ20-160/11 | 146 | 197 | 190 | 130 | 130 | 9 | 80 | 15 |
CJ20-250 | 190 | 235 | 230 | 160 | 150 | 9 | 100 | 17 |
CJ20-250/06 | 190 | 235 | 230 | 160 | 150 | 9 | 100 | 17 |
CJ20-400 | 245 | 292 | 262 | 210 | 180 | 11 | 110 | 17 |
CJ20-400/06 | 245 | 292 | 262 | 210 | 180 | 11 | 110 | 17 |
CJ20-630 | 245 | 294 | 272 | 210 | 180 | 11 | 120 | 21 |
CJ20-630/11 | 245 | 294 | 287 | 210 | 180 | 11 | 120 | 21 |