GV2 water proof mpcb circuit breaker
- GV2 water proof mpcb circuit breaker is mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1A~80A, as 3pole Motor protector a fullvoltage starter to start and stop the motor, under the AC3 load or for the overload and short circuit protection of the equipments.
- Technical parameters
| Product Model | Rated current InA | The adjusting range commuting current for conponents A | The disjoining current commuting value in instant field InA | Order No. |
| GV2-M(ME) | 0.16 | 0.1-0.16 | 1.5 | GV2-M01C |
| 0.25 | 0.16-0.25 | 2.4 | GV2-M02C | |
| 0.4 | 0.25-0.4 | 5 | GV2-M03C | |
| 0.63 | 0.4-0.63 | 8 | GV2-M04C | |
| 1 | 0.63-1 | 13 | GV2-M05C | |
| 1.6 | 1-1.6 | 22.5 | GV2-M06C | |
| 2.5 | 1.6-2.5 | 33.5 | GV2-M07C | |
| 4 | 2.5-4 | 51 | GV2-M08C | |
| 6.3 | 4-6.3 | 78 | GV2-M10C | |
| 10 | 6-10 | 138 | GV2-M14C | |
| 14 | 9-14 | 170 | GV2-M16C | |
| 18 | 13-18 | 223 | GV2-M20C | |
| 23 | 17-23 | 327 | GV2-M21C | |
| 25 | 20-25 | 327 | GV2-M22C | |
| 32 | 24-32 | 416 | GV2-M32C |
- Mian accessories
- Contacts of accessories
| Name of accessories | Code | the types of contacts | Installation place | ||
| Instantaneous auxiliary contacts | AE1 | 1NO/1NC | The front of breaker (1PC can be installed) | ||
| AE11 | 1NO+1NC | ||||
| AE20 | 2NO | ||||
| AN11 | 1NO+1NC | ||||
| AN20 | 2NO | ||||
| fault signal contacts Instantaneous auxiliary contacts | AD1010 | constant-open trouble | NO | the left of the breaker (4PCS can be installed) | |
| AD1001 | NC | ||||
| AD0110 | constant-close trouble | NO | |||
| AD0101 | NC | ||||
| Short circuit contacts | AM11 | 1NO,1NC | |||
- Electric disjointing
| Names of accessorires | Code | voltage (V) | Installation place | ||
| Lacj-voltage disjointing | AU115 | 110-127V 50HZ | The right of breaker (1PC can be installed) | ||
| AU225 | 220-240V 50HZ | ||||
| AU385 | 385-415V 50HZ | ||||
| Division disjointing | AS115 | 110-127V 50HZ | |||
| AS225 | 220-240V 50HZ | ||||
| AS385 | 385-415V 50HZ | ||||
| Be used to the release of low voltage | AX115 | 110-127V 50HZ | |||
| AX225 | 220-240V 50HZ | ||||
| AX385 | 385-415V 50HZ | ||||
- The protective case of breaker
| Name of accessories | The protection grade of case | Code | |||
| External installation shell | IP41 | MC01 | |||
| IP55 | MC02 | ||||
| IP65 | MC03 |
- The external fixing dimension
The outline and fixing dimensoin of breaker (GV2 motor protection circuit breaker )(refer to chart 2 and 3)
The breaker (GV2 motor protection circuit breaker ) adopts the standard rail installation , the rail should meet the A2.1TH35-7.5 type installation standard of JB6525
The external installation dimension of GV2 motor protection circuit breaker (refer to chart 1 and 4)